Idx i200 Manuel d'utilisateur Page 3

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 4
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 2
Battery Protection Features
Following are a list of basic charger protection features for User recognition
* Low voltage battery
A. If the battery voltage is below or equal 5.0V
The battery will not be charged, (no charger LED)
B. If the battery voltage is 5.0~10.5V,
The unit starts conditioning charging (red LED lights) and automatically
starts quick charging when the battery voltage recovers to reach 10.5v. If the
battery voltage does not reach 10.5V after 30 minutes of conditioning,
charging will be stopped (orange LED blinks).
*Over charge protection
If charging does stop due to faulty battery or some other reason, a circuit
protection timer is automatically activated and stops charging.
If the battery is not charged after 260minutes (4 1/2Hrs) of charging, the unit
stops charging. If battery voltage is 13.0V, Green LED lights indicating usable
battery. If the battery voltage does not reach 13.0V, orange LED lights indicating
faulty battery (low capacity). This is usually when it is time to replace your
battery(s).
*Over voltage protection
Over voltage protection circuit stops charging if the battery voltage does not reach
specific figure within specific time.
If the battery voltage reaches or exceeds 21.5V during quick charge is in progress,
charging will be stopped. (Orange LED blinks)
LED COLOR STATUS LIST
Full Red…….….……… fast charge in progress
No LED………….…… charge waiting (when battery inserted)
Full Green………..…… charge complete, trickle charge in progress
Blinking Green……….. discharge in progress
Full Orange……….……discharge waiting
Blinking Orange………..defective battery (check battery specifications)
Blinking Red……….…..defective charger (return for service)
Vue de la page 2
1 2 3 4

Commentaires sur ces manuels

Pas de commentaire